Specialised protective coating systems for mission-critical cooling infrastructure. Ensuring 24/7 reliability for hyperscale, colocation, and enterprise data centres.

Emergency Contact

Data Centre HVAC Challenges

Modern data centres face unique corrosion challenges that threaten cooling reliability and operational uptime.

Extreme Cooling Demands

Modern AI and cloud computing infrastructure generates unprecedented heat loads requiring 24/7 cooling reliability.

Humidity Control

Maintaining 40-60% RH to prevent electrostatic discharge while avoiding condensation and corrosion on critical equipment.

Corrosion-Driven Downtime

Silent corrosion progression can cause catastrophic cooling system failure in mission-critical facilities.

Thermal Efficiency Loss

Corrosion debris fouls heat transfer surfaces, reducing efficiency and violating performance guarantees.

Liquid Cooling Challenges

Next-gen liquid cooling systems face corrosion risks in pipes, heat exchangers, and direct-to-chip components.

System Layup Vulnerability

Backup chillers and cooling towers sitting idle create highly corrosive environments during off-seasons.

Industry Standards Compliance

Our coating systems ensure compliance with international data centre standards and best practices.

ASHRAE TC 9.9

Mission Critical Facilities, Data Centres, Technology Spaces

Requirement:

Temperature: 18-27°C (64-81°F), Humidity: -9°C to 15°C DP

ASHRAE Corrosion Guidelines

High corrosion risk environments

Requirement:

Maintain humidity below 60% RH, preferably below 50% RH

Uptime Institute Tier Standards

Infrastructure reliability and redundancy

Requirement:

99.99% uptime requires corrosion-free cooling systems

Specialised Coating Solutions

Comprehensive protection for every component of your data centre cooling infrastructure

CRAC/CRAH Unit Protection

Computer Room Air Conditioning and Air Handler units require specialised coil coating to maintain thermal efficiency.

Hydrophilic coatings on aluminium fins and copper tubes
Optimised for high-efficiency heat transfer
Protection against condensation and corrosion
Extended equipment lifespan in 24/7 operation

Chiller Coil Systems

Primary and backup chiller protection ensuring continuous operation during peak loads and standby periods.

Vapour phase corrosion inhibitor (VpCI) technology
Dual-phase protection for submerged and exposed components
Flash rust and pitting prevention during idle periods
Maintains chemical water treatment integrity

Cooling Tower Protection

Comprehensive coating systems for cooling towers exposed to environmental contaminants and water quality issues.

Biological growth prevention
Scale and corrosion barrier on heat exchange surfaces
Protection against dust and airborne contaminants
Extended maintenance intervals

Liquid Cooling Infrastructure

Advanced protection for next-generation liquid cooling systems supporting high-density computing.

Direct-to-chip cooling loop protection
Heat exchanger and manifold coating
Leak prevention in fine-bore piping
Specialised maintenance for closed-loop systems

Key Benefits

Why leading data centres trust Arctic Coating for mission-critical protection

Mission Critical Reliability

Prevent catastrophic cooling failures in 24/7 operations

Energy Efficiency

Maintain optimal thermal transfer, reducing energy costs

Extended Equipment Life

Protect multi-million dollar infrastructure investments

Reduced Downtime

Prevent unplanned maintenance and system failures

Compliance Assurance

Meet ASHRAE and Uptime Institute standards

Improved Airflow

Prevent fouling and maintain designed cooling capacity

Proven Results in Australian Data Centres

Real-world implementations protecting mission-critical infrastructure

5MW Capacity

Major Sydney Colocation Facility

Challenge:
Coastal salt air corrosion affecting primary chillers
Solution:
Complete CRAC unit coil coating and chiller protection
Result:
40% reduction in maintenance calls, 15% energy efficiency gain
20MW+ Capacity

Melbourne Hyperscale Data Centre

Challenge:
Backup chiller corrosion during winter layup periods
Solution:
VpCI technology implementation on all standby systems
Result:
Zero corrosion-related failures over 3-year period
Distributed Sites

Edge Computing Facility

Challenge:
High humidity environment affecting cooling towers
Solution:
Comprehensive coating program across 8 locations
Result:
Extended maintenance intervals from 6 to 18 months

Critical Infrastructure Protection

Data centre operators cannot afford cooling system failures. A single corrosion-related breakdown can result in:

  • Catastrophic server downtime affecting thousands of customers
  • SLA violations and significant financial penalties
  • Emergency equipment replacement at premium costs
  • Reputation damage in competitive colocation markets
  • Regulatory compliance issues for critical infrastructure